ALARM BR. 1Jablotron Alarm Systems
    BUS Architecture | JABLOTRON 100+
    JABLOTRON Bus room thermostat with CO2 sensor JB-112TP
    CO₂ Sensor400–5000 ppm
    Temperature-10 to +70 °C
    Humidity0–100% RH
    Catalogue number: JB-112TP

    JABLOTRON Bus room thermostat with CO₂ sensor JB-112TP

    The new advanced Bus room thermostat for the JABLOTRON 100+ system. Continuously monitoring temperature, humidity, and carbon dioxide (CO₂) levels, the JB-112TP automatically manages heating, cooling, and air ventilation for maximum comfort and a healthy indoor microclimate.

    Clear LCD screen and buttons for local in-room temperature adjustments
    High-precision NDIR CO₂ sensor displaying 5 air quality levels
    Integrated control for heat-recovery systems and automated ventilation
    Full management and historical graphs via the MyJABLOTRON 2 application

    One device – triple climate and air quality control

    The JB-112TP thermostat connects directly to the system bus of the JABLOTRON 100+ control panel, ensuring reliable communication without relying on internal device batteries.

    Temperature Measurement

    Enables zoned heating and cooling management. When the alarm is armed (away mode), the system automatically lowers heating setpoints to conserve energy.

    CO₂ (Carbon Dioxide) Sensor

    Measures CO₂ concentration from 400 to 5000 ppm. When thresholds are exceeded, it triggers ventilation or alerts users to ventilate the room.

    Relative Humidity Sensor

    Monitors indoor humidity in real-time from 0 to 100% RH, preventing condensation and mold development in residential and commercial properties.

    Technical Specifications (JB-112TP)

    Official manufacturer specifications from JABLOTRON Alarms

    Connection TypeJABLOTRON 100+ System Bus (Wired)
    Power SupplyFrom the control panel bus (9...15 V DC)
    Current Consumption (standby / max)5 mA / 15 mA
    CO₂ Measurement PrincipleNDIR (Non-Dispersive Infrared) optical sensor with automatic calibration
    CO₂ Measuring Range400 ppm to 5000 ppm (Accuracy: ±50 ppm + 3% of measured value)
    Temperature Measuring Range-10 °C to +70 °C (Accuracy: ± 0.5 °C)
    Humidity Measuring Range0 % to 100 % RH (Accuracy: ± 3 % RH)
    Dimensions88 x 88 x 20 mm
    Operating Temperature Range-10 °C to +40 °C
    Environmental ClassII. indoor general according to EN 50131-1
    CompatibilityJABLOTRON 100+ Control Panels (JA-103K, JA-107K and compatible bus modules)
    Versatile Application

    Where is the JB-112TP thermostat recommended?

    Homes and Apartments: In bedrooms and living rooms where high CO₂ levels overnight directly impact sleep quality and morning freshness.

    Offices and Workspaces: Prevents afternoon fatigue and boosts productivity in meeting rooms and open office spaces.

    Schools and Kindergartens: Ensures optimal climate conditions for children's health and learning capacity with automated alerts.

    Advantages of JABLOTRON 100+ Integration

    • No need for dedicated controllers – uses the existing security system bus and panel.
    • Automated radiator and ventilation PG outputs with scheduled programming.
    • Single MyJABLOTRON 2 application for security, heating, and air quality.
    • Powered directly from the control panel with battery backup during power outages.

    Related Content and Products

    Technical Article / Blog

    How new JABLOTRON thermostats monitor CO₂ and air quality

    Read our in-depth article on carbon dioxide's impact on health and learn how automated ventilation works with JABLOTRON systems.

    Read Blog Article
    Related Product

    JABLOTRON Bus CO₂, Temperature & Humidity Sensor JB-112TH

    Model designed without a screen or buttons for public spaces, schools, and offices to prevent unauthorized adjustment.

    View JB-112TH Buttonless Model

    Frequently Asked Questions about JB-112TP Thermostat

    What parameters does the JABLOTRON JB-112TP thermostat measure?

    The JB-112TP measures three key parameters: carbon dioxide level (CO₂ in ppm), room temperature (°C), and relative air humidity (% RH).

    What type of CO₂ sensor is used and how precise is it?

    It utilizes a high-precision optical NDIR (Non-Dispersive Infrared) sensor with a measurement range of 400 to 5000 ppm and automatic calibration.

    Is the JB-112TP bus-wired or wireless?

    The JB-112TP is a bus device connected directly to the system bus of the JABLOTRON 100+ control panel, from which it also receives power.

    How does the thermostat control heating and ventilation?

    Through the control panel and PG outputs, the thermostat automatically manages heating circuits, air conditioning, heat-recovery ventilation, or automated window actuators. Users can also manually adjust temperature settings locally via physical buttons on the device.

    Can I monitor CO₂ levels remotely?

    Yes, all real-time measurements, historical graphs, and notifications are accessible through the MyJABLOTRON 2 mobile and web application.

    Can I install the JB-112TP thermostat myself?

    The JB-112TP is part of a professional security and automation system. Installation and configuration are carried out by a certified JABLOTRON installation partner to ensure seamless operation and warranty coverage.

    Request a Consultation & Quote for JABLOTRON Thermostats

    Our licensed engineering team, together with certified installation partners, will design a tailored technical solution for your home or business.